Power Cable
0.6/1kV XLPE Insulated and Tray Flame-Retardant PVC Sheathed Cable (TFR-CV)
- ApplicationDesigned for the purpose of using in power distribution line, having excellent flame retardant.
- Construction - Conductors:Annealed Copper Wire
- Insulation : XLPE
- Sheath : FR-PVC
- Color identification : 2 cores-black, white / 3 cores-black, white, red / 4 cores-black, white, red, green - StandardKS C IEC 60502-1/ KETI
0.6/1kV XLPE Insulated and Tray Flame-Retardant PVC Sheathed Aluminium Power Cable(TFR-CV/AL)
- ApplicationDesigned for the purpose of using in power distribution line, having excellent flame retardant.
- Construction- Conductors:AI
- Insulation :XLPE
- Sheath : FR-PVC - StandardKS C IEC 60502-1(KS C IEC 60228 AI 적용)
0.6/1kV XLPE Insulated Halogen-Free Flame Retardant Poly-Olefin Sheathed Power Cable(HFCO)
- ApplicationDesigned for the purpose of using in power distribution line under 0.6/1kV having excellent low smoking & nontoxic and flame retardant.
- Construction- Conductors:Annealed Copper Wire
(concentric circular, compact circular)
- Insulation :XLPE
- Sheath : Halogen-Free Flame Retardant Poly-olefin
- Color identification : Coloring Method(2 Cores - Black, White /
3 Cores - Black, White, Red ) /
White - white or natural color - Class and Symbols0.6/1kV XLPE insulated halogen free flame retardant poly-olefin sheathed power cable- 0.6/1kV HFCO
- StandardKS C IEC 60502-1
0.6/1kV XLPE Insulated PVC Sheathed Flat Cable(CVF)
- ApplicationDesigned for the purpose of using in power distribution line for control system under 0.6/1kV having excellent electrical physical and chemical properties.
- Construction- Conductors:Annealed Copper Wire
- Insulation :XLPE
- Color identification : Colour Tape(3 cores - Black, White, Red) - StandardKS C IEC 60502-1
0.6/1kV XLPE Insulated PVC Sheathed Water-Proof Aluminium Power Cable(CV-W/AL)
- ApplicationDesigned for the purpose of using in power distribution line for control system under 0.6/1kV.
- Construction- Conductors:Circular Compacted Stranded Filled with Water Blocking
Tape Plain Annealed Copper
- Insulation :XLPE
- Sheath : PVC
- Color identification : 1 core - Natural color /2 Cores - Black, White
3 cores - Black, White, Red / 4 cores - Black, White, Red, Green - StandardKS C IEC 60502-1
0.6/1kV PVC Insulated PVC Sheathed Cable(VV)
- ApplicationSuperior weather proof and anti-friction property, permitting of use for a long period of time and widely used under 0.6/1kV grade.
- Construction- Conductors:Annealed Copper Wire
- Insulation :PVC
- Sheath : PVC
- Color identification : 2 cores - Black, White
3 cores - Black, White, Red
4 cores - Black, White, Red, Green - StandardKS C IEC 60502-1
6/10kV XLPE Insulated and Tray Flame-Retardant PVC Sheathed Cable(6/10kV TFR-CV)
- ApplicationDesigned for the purpose of using in power, distribution line, having excellent electrical, physical and chemical properties.
- Construction- Conductors:Annealed Copper Wire (concentric circular, compact circular)
- Insulation :XLPE
- Sheath : FR-PVC
- Color identification : 1 core - Natural color
3 cores - Black, White, Red - StandardKS C IEC 60502-2
6/10kV XLPE Insulated Halogen-Free Flame Retardant Poly-Olefin Sheathed Power Cable(6/10kV HFCO)
- ApplicationDesigned for the purpose of using in power distribution line under 6/10kV having excellent low smoking & nontoxic and flame retardant.
- Construction- Conductors:Annealed Copper Wire
(Concentric Circular, Compact Circular)
- Insulation : XLPE
- Sheath : Halogen Free Flame Retardant Poly-olefin
- Color Identification : Coloring Method
(1 core - Natural /3 cores - Black, White, Red )
White -White or Natural color - Class and Symbols6/10kV XLPE insulated halogen free flame retardant poly-olefin sheathed power cable- 6/10kV HFCO
- StandardKS C IEC 60502-2
22.9kV-y Water-Proof Copper Conductor XLPE Insulated, Concentric Neutral Conductor with Water Swellable Tapes, and PVC(Halogen-Free Poly-Olefin Flame Retardant) Sheathed Power Cable(22.9kV-y CNCV-W, FR CNCO-W)
- ApplicationUsed for 22.9kV-y concentric neutral type water tree retardant XLPE insulated extrude to fill polyethylene jacketed water-proof power cable.
- Construction- Conductors:Circular Compacted Stranded Filled with Water Blocking
Compound or Tape Plain Annealed Copper
- Insulation : 90℃, Extruded Cross-linked Polyethylene with
Semi-conductive Inner and Outer Screen
- Neutral Conductor : Annealed Copper Wire with Water-blocking Tapes
- Sheath : PVC(CNCV-W), Halogen-Free Poly-Olefin(FR CNCO-W) - StandardES 6145-0019
22.9kV-y Water-Proof Aluminium Conductor XLPE Insulated, Concentric Neutral Conductor with Water Swellable Tapes, and Halogen-Free Poly-Olefin Flame Retardant Sheathed Power Aluminium Cable(22.9kV-y FR CNCO-W/AL)
- ApplicationUsed for 22.9kV-y multi-grounded power distribution circuits in industrial and commercial installation. It may be installed on conduit, duct, tray or directly buried. Safe from ingress of humidity.
- Construction- Conductors:Circular Compacted Stranded Aluminium Filled with
Water Blocking Compound or Tape
- Insulation : 90℃, Extruded Cross-linked Polyethylene with
Semi-conductive Inner and Outer Screen
- Neutral Conductor : Annealed Copper Wire with Water-blocking Tapes
- Sheath : PVC - StandardGS-6145-0068
22.9kV-y Water-Proof Copper Conductor TR-XLPE Insulated, Concentric Neutral Conductor with Water Swellable Tapes, and Polyethylene Flame Retardant Sheathed Power Cable(22.9kV-y TR CNCE-W)
- ApplicationUsed for 22.9kV-y concentric neutral type water tree retardant XLPE insulated extraded-to-fill polyethylene jacketed water-proof power cable.
- Construction- Conductors:Circular Compacted Stranded Filled with Water Blocking
Compound or Tape Plain Annealed Copper
- Insulation : 90℃, Extruded Cross-linked Polyethylene with
Semi-conductive Inner and Outer Screen
- Neutral Conductor : Annealed Copper Wire with Water-blocking Tapes
- Sheath : PVC - StandardES 6145-0025
22.9kV-y Water-Proof Aluminium Conductor TR-XLPE Insulated, Concentric Neutral Conductor with Water Swellable Tapes, and Polyethylene Flame Retardant Sheathed Power Aluminium Cable(22.9kV-y TR CNCE-W/AL)
- ApplicationUsed for 22.9kV-y concentric neutral type water tree retardant XLPE insulated extraded-to-fill polyethylene jacketed water-proof power Aluminium cable.
- Construction- Conductors:Circular Compacted Stranded Aluminium Filled with
Water Blocking Compound or Tape
- Insulation : 90℃, Extruded Cross-linked Polyethylene with
Semi-conductive Inner and Outer Screen
- Neutral Conductor : Annealed Copper Wire with Water-blocking Tapes
- Sheath : PVC - StandardES-6145-0026